Fire Training Tower

Fire Training Tower for Ladder, Rescue and Hose Drills

Fire Training Tower is planned around the drills your crews actually run. Floor count, practice windows, stairs and roof access can be changed before fabrication, so the finished tower suits the training ground instead of forcing every department into one standard layout.

Fire Training Tower projects usually begin with a list of drills, not a catalogue model. A four-floor tower is the usual minimum. A department serving a high-rise district may want extra levels, while a smaller station may put more value on an open stair tower and a clear ladder face.

The front wall normally has two practice windows on each floor. Their size and spacing matter because crews need a repeatable setup for ladder placement and entry work. Inside, the floor platforms and stairs give instructors a safe way to move between levels without crossing the working face.

Some customers choose a closed facade with window openings. Others want an open frame so the stairs and platforms remain visible during instruction. Both versions can be shipped in bolted sections. Hot-dip galvanizing or thermal-spray coating is applied after the steelwork has been prepared.

Add only what the crews will use

A roof command platform is common, but the remaining equipment depends on the training programme. Options include a hose-drying rack, pulley, sliding pole, practice wall and wind instrument. If confined-space drills are required, a separate training well can be planned beside the tower instead of being added after installation.

Specifications

Number of floorsFour floors minimum; additional floors available for the training plan
Typical floor height3.5 m
Practice windowsAt least two on each front floor
Window opening1.2 × 1.8 m
Window spacing1.0 m wall between windows; at least 0.65 m from window to tower edge
Window sill0.4 m wide, projecting 50 mm; sill height 0.8 m above the floor
Internal stairClear width of at least 0.7 m
Internal platformAt least 1.5 m wide on each level
External fire ladderAt least 0.5 m wide; may start 3 m above ground and continue to the roof
Top levelRoof floor with guarded lookout and command platform
AssemblyBolted facade panels, floor plates, rear frame and main steel structure
Corrosion protectionHot-dip galvanizing or thermal-spray coating with finish coat
Optional equipmentHose rack, pulley, sliding pole, practice wall, alarm, wind instrument or training well
Design service lifeUp to 50 years subject to design, coating, site exposure and maintenance

A marked-up sketch is enough to begin. Show the number of floors, windows on each level, preferred stair position and any training equipment you want us to include.

Applications

Most towers go to fire stations and municipal training grounds. We also make them for industrial fire teams and emergency training centres that need a permanent structure for regular ladder, rescue and hose practice.

Our Products